The characteristic strength, stiffness and density properties for glued hybrid beams made of beech/spruce shall be taken from Table 5. For strength- and Stiffness properties not covered by Table 5 the values shall be taken as values for GL 24h according to DIN 1052: 2008-12, Table F.9.
For the verification of the compression perpendicular to the grain stresses in accordance with DIN 1052 a coefficient of kc,90 =1 shall be taken into account for the design of the beech laminations for all cases.
In addition, the compression perpendicular to the grain stresses of the softwood core laminations shall be verified whereby a stress propagation of 45° in the outermost laminations must be assumed. The coefficients kc,90 in accordance with DIN 1052 for the different cases of support may be used.
For the design of joints the provisions of DIN 1052 or DIN EN 1995-1-1the provisions for hard- and softwood (in the case of hybrid beams) apply accordingly. The rules given above are also applicable for a design according to
DIN EN 1995-1-1. Additionally kcr has to be taken as kcr = 1.
Table 5: Characteristic strength, stiffness and density values for hybrid beams made of beech/spruce of differing strength classes (in N/mm2)
|
GL 28 hyb |
GL 32 hyb |
GL 36 hyb |
GL 40 hyb |
GL 44 hyb |
GL48 hyb |
Characteristic strength values |
fm,ka |
28 |
32 |
36 |
40 |
44 |
48 |
fv,k |
2,5 |
Characteristic stiffness values |
E0, mean |
13200 |
13200 |
13200 |
14000 |
14700 |
14700 |
E0,05 |
12400 |
12400 |
12400 |
13300 |
14200 |
14200 |
Characteristic density values for softwood laminations (kg/m3) |
Ρk |
380 |
a |
If the laminations are subject to flat-wise bending in the case of beams of height < 600 mm, the characteristic strength may be multiplied by the coefficient |
kh =
If h > 600 mm the characteristic strength shall be multiplied by a coefficient of
kh = |
Openings in glued laminated timber made of beech or hybrid beams made of beech/spruce are not permissible.
When using mechanical fasteners the regulations stipulated by DIN 1052 or technical approvals for the appropriate fasteners must be observed. The facilitation given in DIN 1052:2008-12, 12.5.2(10), may not be applied to glued laminated timber made of beech or in the outermost laminations of hybrid beams made of beech/spruce.